Para casa > produtos > Medidor de fluxo de Digitas >
100% New Original Proline Promass I100 8I1B Ultra-Compact Transmitter In-Line Viscosity Flow Measurement OEMFor E Ndress H Auser

100% New Original Proline Promass I100 8I1B Ultra-Compact Transmitter In-Line Viscosity Flow Measurement OEMFor E Ndress H Auser

Proline Promass I100 flow meter

ultra-compact viscosity transmitter

in-line flow measurement OEM

Lugar de origem:

CHINA

Marca:

E+H

Número do modelo:

8i1b

Converse agora
Solicite um orçamento
Detalhes do produto
Tensão de fornecimento:
10-30 VDC
Princípio de medição:
Pressão absoluta e de medidor
Conexão do processo:
1/2 "NPT
Tipo de montagem:
Rosqueado
Conexão elétrica:
M12x1
Precisão de referência:
Padrão: 0,05% de platina: até 0,025%
Sinal de saída:
4-20 Ma
Método de montagem:
Din Rail ou Wall Mount
Protocolo:
Hart/RS485
Faixa de temperatura:
-40 a 185°F
Faixa:
0-10.000 psi
Material de peças molhadas:
Aço inoxidável
Material:
Aço inoxidável
Protocolo de comunicação:
Hart
Temperatura operacional:
-20 a 85 graus Celsius.
Destacar:

Proline Promass I100 flow meter

,

ultra-compact viscosity transmitter

,

in-line flow measurement OEM

Termos de pagamento e envio
Quantidade de ordem mínima
1 pc
Preço
USD 600
Tempo de entrega
7-14 dias
Termos de pagamento
T/T.
Habilidade da fonte
100 pc
Descrição do produto

What is the Promass I 100

The Promass I 100 is a high-performance Coriolis mass flowmeter designed for industrial applications, offering measurements of mass flow, density, and temperature, with optional viscosity measurement.

It is part of the Endress+Hauser “Promass I” line, featuring a straight single-tube sensor design and very compact transmitter housing.

 

Measuring principle

  • The fundamental principle is Coriolis force measurement: the flow tube is vibrated and the fluid flowing through causes a phase shift in oscillations between inlet & outlet positions. This phase shift is proportional to mass flow.
  • The tube is excited at its resonance; changes in oscillation frequency due to changes in mass (tube + fluid) are used to compute density.
  • Temperature of the measuring tube is also measured, both for fluid temperature and to compensate temperature effects.

 

Key Technical Features & Specifications

Here are some of its important characteristics:

Feature

Details

Flow variables measured

Mass flow, density, temperature; optional viscosity.

Sensor design

Straight single-tube design; “easy cleanable”.

Tube material / wetted parts

Titanium for measuring tube; other parts in stainless steel or coating depending on version.

Size range (nominal diameter)

DN 8 to DN 80 (≈ 3/8″ to 3″).

Accuracy

• Liquids: about ±0.1 % for mass & volume flow; <-- density accuracy in liquid ~ ±0.0005 g/cm³.
• Gases: larger error, e.g. approx ±0.5 % mass flow.

Temperature / Pressure ranges

Medium temperature: from 50 °C up to approx +150 °C.
Process pressure: up to PN100 (or equivalent), specifics depending on DN, material etc.

Environmental / Protection

High ingress protection (IP69K in many versions). Robust transmitter housing.

Installation

“Full-bore” design to minimize pressure drop. As its straight tube, less demanding for inlet/outlet runs compared to bent-tube designs.

Outputs / Communication

Multiple typical industrial outputs: analog (4-20 mA with HART), digital protocols (Modbus RS-485, PROFIBUS, PROFINET, etc.), pulse/frequency/switch outputs.

Additional features

Integrated web server for local configuration, diagnostics. “Heartbeat Technology” for verification and monitoring.

 

Advantages

  • High accuracy and stability: Since the measurement is mass‐based and not strongly influenced by fluid viscosity, density, or flow profile, it gives very reliable readings.
  • Multi-variable measurement: Flow, density, temperature (and viscosity optionally) reduce need for multiple sensors.
  • Compact & robust: Small footprint transmitter, full-bore, straight tube helps in installations where space is limited and/or cleaning is needed.
  • Low pressure loss: Full bore and straight single tube help minimizing pressure drop. Good for sensitive fluids.
  • Good for hygiene and cleaning: Because of the easy-clean straight tube. Also options exist for hygienic/stainless housing.

 

Limitations / Considerations

  • Cost tends to be relatively high vs simpler flowmeters. More sophisticated construction, more electronics.
  • For very low flow or very small diameters, sensitivity and signal-to-noise becomes more challenging need to check minimum flow (cut-off) for your application.
  • The wetted materials (Titanium, stainless) have to be compatible with the fluid (chemically, abrasive, etc.). If the fluid is aggressive or contains solids, consider wear or corrosion.
  • Temperature and pressure limits: depending on the exact model; ensure your process operating envelope fits within them.
  • Maintenance might require more care (cleaning, calibration) due to the precision of the instrument.

 

Typical Applications

The Promass I 100 is suitable for many industrial sectors, especially where accurate mass flow + density + temperature are needed, such as:

  • Chemical process lines
  • Food & beverage where hygiene / cleaning is required
  • Pharmaceuticals
  • Oil & gas (for certain liquids/gases)
  • Skid / module builders (because of compact size)
  • Any application where pressure drop must be minimized or full-bore is preferable.

 

Envie a sua consulta directamente para nós

Política de Privacidade China bom Qualidade Transmissores de pressão industriais Fornecedor. Copyright © 2024-2025 Xi'an Xiyi Central Control Technology Co., Ltd. Todos. Todos os direitos reservados.