Para casa > produtos > transmissor nivelado >
Hot Sale E+H Conductive Point Level Switch Liquipoint T FTW31, FTW32 FTW31-A1A3AA4A 400mm

Hot Sale E+H Conductive Point Level Switch Liquipoint T FTW31, FTW32 FTW31-A1A3AA4A 400mm

E+H conductive level switch

Liquipoint T FTW31 level transmitter

400mm point level sensor

Lugar de origem:

Alemanha

Marca:

E+H

Número do modelo:

FTW31

Converse agora
Solicite um orçamento
Detalhes do produto
Classificação de proteção:
IP67
Aplicativo:
CONTROLE DE PROCESSOS INDUSTRIAL
Tipo de pressão:
Pressão do medidor
Temperatura de armazenamento:
-40 a 85 graus Celsius
Materiais molhados:
316L Aço inoxidável
Faixa:
0-10.000 psi
Modelo:
Transmissores de Pressão Industriais
Classe de proteção:
IP67
Material de peças molhadas:
316L Aço inoxidável
Faixa de temperatura:
-40 a 185°F
Tempo de resposta:
≤10 ms
Peso:
0,5 kg
Proteção de entrada:
IP67
Temperatura operacional:
-40 a 85 ° C.
Sinal de saída:
4-20 Ma
Destacar:

E+H conductive level switch

,

Liquipoint T FTW31 level transmitter

,

400mm point level sensor

Termos de pagamento e envio
Quantidade de ordem mínima
1 pc
Preço
USD 500 1 pc
Tempo de entrega
7-14 dias
Termos de pagamento
T/T.
Habilidade da fonte
100 pc 1 semana
Descrição do produto

What is Liquipoint FTW31

The Liquipoint FTW31 is a conductive pointlevel detector (point level switch) designed for liquids that conduct electricity. It’s used to detect when the liquid reaches a certain level (or multiple levels) in a tank or vessel — for example: overfill protection, dry-run protection of pumps, controlling pump start/stop between two levels, etc.

Unlike continuous level sensors, it detects at specific points (electrodes/rods) rather than giving the whole level profile.

 

How it Works (Measuring Principle)

  • It uses conductive probing electrodes (rods). The liquid must be conductive (minimum conductivity required) so that when the liquid touches the probes, a circuit completes via the liquid, signalling that level is reached.
  • The FTW31 can have multiple switching points on a single probe: up to 5 rods/electrodes meaning you can detect multiple distinct levels with one probe.
  • There are no moving parts, which helps reduce wear and maintenance.

 

Key Specifications

Here are the typical technical data you should know about:

Spec

Value / Range

Process (media) conductivity minimum

~ 10 µS/cm

Process temperature

40 °C to +100 °C

Ambient temperature

40 °C to +70 °C

Process pressure

Vacuum up to approx. +10 bar

Probe (sensor) length

0.1 m to 4 m (≈ 10 cm to 400 cm)

Process connection

Threaded connection types (e.g. G-threads, possibly NPT)

Wetted materials

Commonly stainless steel 316L, sometimes plastics like PP or PPS for insulation / housing parts.

Output / signal types

Can be relay output, DC PNP, etc.

 

Advantages

Some of the benefits of using FTW31:

  • Multipoint detection with one probe: Up to 5 switch points allow you to monitor several levels with one sensor. Saves cost and simplifies installation.
  • Simple, robust construction: No moving parts → more reliable, less wear, less maintenance.
  • No calibration required for many common conductive liquids; standard settings are provided.
  • Wide temperature and pressure range suitable for many industrial processes.
  • Good for safety applications like overfill prevention, dry-run protection, etc.

 

Limitations & Considerations

Things to check / watch out for:

  • The liquid must have sufficient conductivity (at least ~ 10 µS/cm). If the liquid is very pure (low ion concentration) and non-conductive, the detector may not work reliably.
  • Build-up or deposition on the electrodes (scale, sludge, etc.) can affect performance. If the probes are coated or partially insulated, detection may be delayed or false.
  • Multiple rods means multiple exposed points; electrical insulation and mounting must prevent false triggering via unintended paths (e.g. via tank wall, mounting brackets, or condensation).
  • In aggressive or corrosive liquids, material compatibility (electrode/stem housing) is important.
  • Safety/environmental/explosion certifications must match the application when in hazardous areas. FTW31 offers these, but the specific version and installation must comply.

 

Envie a sua consulta directamente para nós

Política de Privacidade China bom Qualidade Transmissores de pressão industriais Fornecedor. Copyright © 2024-2025 Xi'an Xiyi Central Control Technology Co., Ltd. Todos. Todos os direitos reservados.